Product Info£º
Main Features:
¡ôOutput power range:500VA-180kVA;
¡ôSingle-phase AC output:115V,¡À20%adjustable;Three-phase AC output:115V/200V(or 21/36V), ¡À20% adjustable;
¡ôOutput frequency adjustable: (1)400Hz settled frequency output (2)320-480Hz alterable frequency;
¡ôAdopt ARM control, comes with serial communication interface, can connect with computer through remote communication control;
¡ôAdopt intelligent IGBT(IPM) output, excellent protection function;
¡ôAdopt SPWM technology, small size, light weight, and low noise;
¡ô120¡ãphase lock, create up to three-phase output through single-phase product of phase locking;
¡ôIsolated transformer output for additional durability;
¡ôSupply pure and stable sine wave power, waveform distortion rate better than 2%,output voltage adjustable up to ¡À20%;
¡ôFast output: steady within 2ms,100% load change, linear load steady is ¡À1% immediately;
¡ôStrong overload capacity, able to run continuously within 120% of its capacity. When operate at 150%,supply voltage will be disconnected in 600s,and 15s when operate at 200%
Standards:
¡ôInternational Standard Organization:ISO6858
¡ôUSA Aviation Standard:MIL-STD-704E
¡ôChina Aviation Standard:GJB572-88
¡ôChina Civil Aviation Standard:MH/T6018-1999
Technical Parameters:
|
Model |
AN17001ST£¨F£© |
|
Output Capacity |
1.5kVA |
|
Rated Output Current |
2.9A |
|
AC Input |
Input Voltage |
380V ¡À40V 3-Phase 4-line Input |
|
Input Frequency |
50/60Hz¡À5Hz |
|
AC Output |
Output Voltage |
¢ÙRated Output Voltage:115V(phase)/200V(Line)
¢ÚAdjustable Output Voltage:10V-150V(phase)/17-260V(Line) |
|
Output Freq. |
¢ÙRated Output Frequency:400Hz¡À0.4Hz
¢ÚAdjustable Output Frequency:320-480Hz |
|
Instantaneous
Characteristics |
Meet with MH/T 6018-1999 requirement |
|
Wave distortion(THD) |
¡Ü2% (Resistive load) |
|
Wave Peak Factor |
¡Ü1.41¡À0.10 |
|
Harmonic Content |
¡Ü1.5% |
|
Voltage Module Rate |
¡Ü2.5V |
|
DC Content |
¡Ü¡À0.1V |
|
Display (4-bit) |
Frequency |
(Highest)Resolution: 0.1Hz MAX Permitting Error: ¡À0.1% |
|
Voltage |
(Highest)Resolution:0.1V MAX Permitting Error: ¡À2V |
|
Current |
(Highest)Resolution 0. 1A MAX Permitting Error: ¡À2.5% |
|
Efficiency |
¡Ý85% |
|
Unbalanced Load on three phase |
MAX difference per phase ¡Ü3V |
|
Phase Displacement |
120¡ã¡À2¡ã(under symmetric load and dissymmetric load of 10% rated current ) |
|
Preset Function |
Preset output voltage, output frequency, output voltage upper and lower percent |
|
Memory Function |
Memory voltage, frequency preset value |
|
Alarm Function |
Alarm signal after protection action |
|
Protection Function |
Input lack-phase protection, input short-circuit protection, over-heat protection, output lack-phase protection,
Remark:(Display corresponding code) |
|
Over Load Capacity |
With in 120% can continues run, when 125% 600s cut, when 150% 60s cut, when 200% 15s cut.
(Remark: Load of power factor is 0.8) |
|
Noise |
¡Ü70dB(A) |
|
Display Mode |
LED |
|
Chassis Mode |
Stand-up |
|
Dimension W¡ÁH¡ÁD£¨mm£© |
400¡Á650¡Á675 |
|
Case Protection Class |
Inner:IP2X;0¡æ-+40¡æ(Standard Series, Low Voltage Output Series) External: GJB 1440 Class 3 Category I -20¡æ~+50¡æ (Mobile Trailer Mode) |
|
Accessories Optional |
¢ÙAircraft Ground Connector(PJD-450HT or PJD-450HTB);
¢ÚAviation Cable(10m,15m or 20m) |
|