HOME>> Product >> Electrical Safety Tester >> Electrical Safety Analyzer :
Product

Desktop Style Electrical Safety Comprehensive Tester:AN9640C(F)

Sum Mary :

Product Infoㄩ

Main features
↑Compliant with IEC60335-1,GB4706 standard requirements;
↑Blue LCD display, all measurement parameters are displayable;
↑Equip with custom design high speed test programs;
↑Compact size, no built-in transformer

Technical parameters

Model
AN9640C (F)
Display Mode
240℅128LCD Large Screen
Over-current Production Limit
When Current 30A,exceed 5s protection
Alarm Mode
Alarm With sound and light
Standard Interface
RS232 interface, Alarm Light interface, Remote Control interface,AN97 Frequency Converter Power Supply interface
Function Optional
RS485 interface, Printer interface, Foot Pedal interface, On-off interface
Buzzer Alarm Sound
Can ON and OFF
Test Group
15 Groups,7 test steps/group
Ground Bond Test
No-load Output Voltage
<12V
Current Presetting Range
AC 3A~30A 50Hz/60Hz 1A/step
Current Accuracy
㊣(1.5% of setting+0.40A)
Current Stability
<0.4%(Current is 10A,100 m次)
Resistance Range/Accuracy
10~600m次 ㊣(1.5% of reading+1.5% of Range)
Resistance Upp-Limit Range
3A≒Current≒10A:10~600 m次;
11A≒Current≒25A:10~300 m次;
26A≒Current≒30A:10~200 m次 1 m次/step
Resistance Low-Limit Range
0 m次
Compensation Resistance Range
0~200 m次 Automatic Measurement, ON/OFF
Voltage Range/Accuracy
30~7500mV ㊣(1.5% of reading+1.5% of Range)
Voltage Upp-Limit Range
30~7500mV 1mV/step
Voltage Low-Limit Range
0mV
Compensation Voltage Range
0~1000mV,Automatic Measurement, ON/OFF
Test Time Range/Resolution
1~999s 1s/step
Insulation Resistance Test
Rated Output Load/Current
2VA(1000V/2mA) 2mA
Output Voltage Range/Resolution
DC 500V/1000V <1% (From no load to full load)
Output Voltage Ripple
<1% (Pure Resistive 1000V/1mA
Output Voltage Accuracy/Resolution
㊣(3% of setting+3V) 5V
Resistance Range/Accuracy
≒200M次: ㊣(3% of reading+3 counts)
>200M次: ㊣(8% of reading+8 counts)
Resistance Upp-Limit Range
2000M次
Resistance Low-Limit Range
0.3~2000M次 0.1M次/step(≒100M次),1M次/step(>100M次)
Test Time Range/Resolution
1~999s 1s/step
AC Hipot Test
Rated Output Load
100VA (AC:5000V/20mA)
Output Voltage Range/Freq./Resolution
500~5000V 50Hz/60Hz <3%(From no load to full load)
Output Voltage Setting Range/Accuracy
Static:AC,500~5000V; ㊣(3% of setting+10V)
Breakdown Current Meas. Accuracy
㊣(3% of setting+0.03mA)
Breakdown Current Alarm Presetting Range
Upp-limit:0.10~20.00mA;
Low-limit:0.03~10.00mA; 0.01mA/step
Compensation Current Range
0.00~10.00mA.Automatic Measurement, ON/OFF
Test Time Range
1~999s 1s/step
Rise Time Range
0~100s 1s/step
Power Test
Output Voltage Range
1.00 times of input voltage(output by isolated transformer)
Power setting Range/Resolution
Upp-limit:6~6000W Low-limit:0~6000W 1W/step
Output Voltage Meas. Range/Accuracy
AC60~280V/45~65Hz: ㊣(0.5% of reading+2 counts)
Current Meas. Range/Accuracy
AC0.030~3.999A,4.00~25.00A;
45~65Hz: ㊣(0.5% of reading+0.020A)
Real-power Meas. Range/Accuracy
100~199.9W: ㊣(0.5% of reading+5W)
200~6000W: ㊣(0.5% of reading+30W)
Power Factor Meas. Range/Accuracy
0.100~1.000; ㊣(2% of reading+2 counts)
Test Time Range
1~999s 1s/step

PreviousDesktop Style Electrical Safety Comprehensive Tester:AN9640B(F)
NextElectrical Safety Comprehensive Tester:AN9651B(F)