HOME>> Product >> Electrical Safety Tester >> Hipot / Insulation Resistance Tester :
Product

AC/DC Hipot/Insulation Resistance Tester:AN9636H(F)

Sum Mary :

Download :

Product Info£º

Main features
¡ôCompliant with IEC60335-1,GB4706 standard requirements;
¡ôLarge blue LCD display, with key parameters display in large font size;
¡ôSmart judgment in large window and alarm function;
¡ôSupports both Chinese and English, simple and convenient operations;
¡ôUser limitation verification, with 8 programmable groups;
¡ôRise-time control function;
¡ôUpper and lower limit alarm, open and short circuit alarm protection;
¡ôAutomatic high speed test, auto-shift function.

Technical parameters

Model
AN9636H(F)
AC/DC Hipot/Insulation Resistance
             AC Hipot Test
Output Voltage Setting / Test Range
100V~5000V AC  100mA    1V/step
Output Voltage Adjustments
 ¡À(2% of setting+5V)
Output Voltage Resolution/ Accuracy
10V, ¡À(2% of setting+5V)
Output Frequency Range/ Accuracy
50Hz/60Hz,  ¡À100ppM
Output Voltage Waveform
Sine wave for pure resistive load , > 200V, distortion <2%, 100V-200V< 5%
Breakdown Current Alarm Upper and Lower Limit Setting Range
Upper limit 0.00~99.99mA, 0.01mA/step
Lower limit 0.000~9.999mA, 0.001mA/step
Breakdown Current Range
0.000~3.500mA/3.50~99.99mA
Breakdown Current Resolution
0.001mA/0.01mA
Breakdown Current Accuracy
< ¡À(2% of reading+3counts)
Rise Time /Fall time/Test Time Range
0.0~999.9s/0.0~999.9s   0.1s/step
Offset Cancellation Function
0~2.000mA,  Auto or manual offset compensation
                   DC Hipot Test
Output Voltage Setting and Range
100V~6000V  DC 10mA    1V/step
Output Voltage Regulated Rate
 ¡À(2% of setting+5V)
Resolution and Accuracy
10V, ¡À(2% of setting+5V)
DC Ripple Quotient
No load¡Ü2%, Full load¡Ü5%(under 6kV DC/10mA)
Breakdown Current Alarm Upper and Lower Limit Setting Range
Upper limit 0.0~9999¦ÌA, 1¦ÌA/step
Lower limit 0.000~999.9¦ÌA , 0.1¦ÌA/step
Upper//Low Limit Setting Range of DC Rising Current
12mA, ON / OFF optional / 0.0~350.0¦ÌA
Breakdown Current Measurement Range
0.0~350.0¦ÌA /300~3500¦ÌA/3.00~9.99mA
Breakdown Current Measurement Resolution & Accuracy
0.1¦ÌA /1¦ÌA /0.01mA   <¡À(2% of reading+3counts)
Rise-Time Setting and Measurement Time Range
0.0~999.9s/0.5~999.9s  0.1s/step
Offset Cancellation Function
0~200¦ÌA, Auto or manual offset compensation
Insulation Resistance Test
Output Voltage Setting and Range
100V~1000V DC   1V/step
Output Voltage Resolution and Accuracy
1V, ¡À(2% of setting+5V)
DC Ripple Quotient
No load¡Ü1% ,Full load<5%(under 1K DC/1mA)
Output Voltage Regulated Rate
¡À(2% of setting+5V)
Test time Setting Range
0.5~999.9s    0.1s/step
Lower limit Setting Range of Insulation Resistance
1~9999M
Upper limit Setting Range of Insulation Resistance
0~9999M
Lower Limit Setting Range of DC Charging Current
0.000~3.500¦ÌA
Insulation Resistance Range
1~9999M, automatic gear shift,4 digit display
Insulation Resistance Measurement Accuracy
500~1000V: ¡À(2% of reading+2counts)1~200M;
¡À(5% of reading+2counts)200~1000M,
¡À(15% of reading+2counts)1000~9999M,
Below 500V: ¡À(8% of reading +2counts) 1~1000M
 ¡À(15% of reading +2counts) 1000~2000M
Dimension(W¡ÁH¡ÁD) (mm)
Desktop style:400¡Á156¡Á475

Previous£º AC/DC Hipot Tester:AN9634H(F)
Next£º Desktop Style Electrical Safety Comprehensive Tester:AN9640B(F)