Product Info:
◆Compliant with IEC60335-1.IEC601-1,JJG984-2004 standard requirements;
◆30A,AC constant output,50Hz/60Hz frequency output;
◆LCD display model available;
◆Upper and lower limit set, auto test, test line clear to zero;
◆Intelligent judgment, voice and light alarm, large font display;
◆8-group and 8-step test condition memory;
◆Advanced PWM control and DSP technical
◆High accuracy, high efficiency, large capacity, small volume
|
Model |
AN9613H(F) |
|
AC Output |
Current |
3.0~30.0A |
|
Voltage |
AC 10V MAX |
|
Frequency |
50Hz/60Hz ,optional ±100ppM |
|
Parameter Setting |
Setting Range of Current |
AC 3.0~30.0A |
|
Current Resolution |
0.1A |
|
Upper Limit Setting of Resistance |
1mΩ~1000mΩ |
|
Lower Limit Setting of Resistance |
1mΩ~1000mΩ |
|
Resistance Resolution |
1 mΩ |
|
Test Resistance Accuracy |
±(2%of upper/lower setting+2mΩ) |
|
Upper Limit Setting of Voltage |
0.00~10.00V |
|
Lower Limit Setting of Voltage |
0.00~10.00V |
|
Voltage Resolution |
0.01V |
|
Test Voltage Accuracy |
±(1% of upper/lower setting +0.02V) |
|
Test Time Range |
0.5~999.9s (0=continuous) |
|
Time Resolution |
0.1s |
|
Measuring Function |
Current Range |
AC 3.0~32.0A |
|
Current Resolution |
0.1A |
|
Current Accuracy |
±(1% of reading+4 counts) |
|
Resistance Range |
1mΩ~1000mΩ |
|
Resistance Resolution |
1mΩ |
|
Resistance Accuracy |
±(2% of reading+2counts) |
|
Auto Reset to Zero Range |
1mΩ~1000mΩ auto/manual |
|
Voltage Range |
AC 0.00~10.00V |
|
Voltage Resolution |
0.01V |
|
Voltage Accuracy |
±(1% of reading+2counts) |
|
Auto Reset to Zero Voltage |
0.00~1.00V auto/manual |
|
Display |
LCD display |
|
Measure Mode |
4-lines |
|
Interface |
RS232(RS485 optional), Printer
Start, Stop, Select memory setting 1-8 input, Pass, Fail, Testing, Error output |
|
Dimension (W×H×D) (mm) |
400×156×475 |
|