Product Info£º
¡ôVoltage ramp-up/ramp-down function, accords with new standard requirements
¡ôUpper and lower limit leakage current preset function, intelligent judgment, voice and light alarm
¡ôSupports both 50Hz and 60Hz
¡ôOver voltage, over current protection, Test line clears to zero by Manual
¡ôAdopt VFD display, simple operation
¡ôRemote interface, RS232/485 interface function
¡ôSmaller size and more beautiful appearance.
|
Model |
AN9605X(F) |
|
AC Hipot Test |
|
Rated Output |
100VA (AC: 5kV/20mA) |
|
Output Voltage Set and Range |
0.2kV¡«5.00kV AC, 10V/step |
|
Output Voltage Adjustable Rate |
¡À(2.5% of setting+10V) |
|
Output Voltage Resolution/Accuracy |
10V, ¡À(2.5% of setting+10V) |
|
Output Frequency Range |
50Hz, 60Hz (Optional) |
|
Output Waveform |
Sine waveform, pure resistance, above 200V, distortion <5% |
|
Upper and Lower Limit Leakage Current Setting |
AC: Upper: 0.10¡«20.00mA, Lower:0.10¡«20.00mA(0=disable), 0.01mA/step |
|
Leakage Current Measurement Range |
0.100¡«3.499mA/3.50¡«20.00mA |
|
Leakage Current Resolution |
0.001mA/0.01mA |
|
Leakage Current Accuracy |
¡À(2.5% of reading+5 counts) |
|
Ramp-up Time Setting Range/Resolution |
1.0¡«999.9s (0=disable) 0.1s/step |
|
Test Time Setting Range/Resolution |
1.0¡«999.9s (LLL=continues) 0.1s/step |
|
Breakdown Current Measurement Range |
AC:0.00¡«40.0mA
DC:0.00¡«10.0mA |
|
DUT Abnormal Processing |
Buzzer alarm, Light alarm |
|
Test Line Clear to Zero |
0¡«0.500mA, manual clear offset |
|
General Parameter |
|
Interface Function |
RS232(RS485 optional), Remote control(PLC) |
|
Dimension W¡ÁH¡ÁD(mm) |
320¡Á110¡Á400 |
|