Main features
¡ôVoltage ramp-up/ramp-down function, accords with new standard requirements
¡ôUpper and lower limit leakage current preset function, intelligent judgment, voice and light alarm
¡ôSupports both 50Hz and 60Hz
¡ôOver voltage, over current protection, Test line clears to zero by Manual
¡ôAdopt VFD display, simple operation
¡ôRemote interface, RS232/485 interface function
¡ôSmaller size and more beautiful appearance.

Technical parameters

Model
AN9605X(F)
AC Hipot Test
Rated Output
100VA  (AC: 5kV/20mA)
Output  Voltage Set and Range
0.2kV¡«5.00kV AC,  10V/step
Output Voltage Adjustable Rate
¡À(2.5% of setting+10V)
Output Voltage Resolution/Accuracy
10V, ¡À(2.5% of setting+10V)
Output Frequency Range
50Hz, 60Hz (Optional)
Output Waveform
Sine waveform, pure resistance, above 200V, distortion <5%
Upper and Lower Limit Leakage Current Setting
AC: Upper: 0.10¡«20.00mA,  Lower:0.10¡«20.00mA(0=disable), 0.01mA/step
Leakage Current Measurement Range
0.100¡«3.499mA/3.50¡«20.00mA
Leakage Current Resolution
0.001mA/0.01mA
Leakage Current Accuracy
¡À(2.5% of reading+5 counts)
Ramp-up Time Setting Range/Resolution
1.0¡«999.9s (0=disable)   0.1s/step
Test Time Setting Range/Resolution
1.0¡«999.9s (LLL=continues)   0.1s/step
Breakdown Current Measurement Range
AC:0.00¡«40.0mA  
DC:0.00¡«10.0mA
DUT Abnormal Processing
Buzzer alarm, Light alarm
Test Line Clear to Zero
0¡«0.500mA, manual clear offset
General Parameter
Interface Function
RS232(RS485 optional), Remote control(PLC)
Dimension  W¡ÁH¡ÁD(mm)
320¡Á110¡Á400